Details
Solar Pump Station c/w:
- Solar 15-80 circulation pump
- 3/4" F return connections
- Flow meter scale 3 - 10 l/min
- Max. working pressure 10 bar
- Safety relief valve temperature range -30°C to +160°C
- Magnetic balancing valve with flow meter temperature range -30°C to +130°C
- Max percentage of Glycol 50%
- SRV set to 6 bar
- Supply 230 volts
- Pre-formed insulation shell
Pump station series 266 is also available with an integrated controller. The above specification pump station with integrated controller is Product code 266254. Please see below for additional pump station units with alternative flow meter scales, with or without controller.
- Flow meter scale 2 - 7 l/min without controller product code 266050 With controller product code 266250
- Flow meter scale 7 - 25 l/min without controller product code 266052 With controller product code 266252



© 2010 Renewable Energy Centres.